Product was successfully added to your shopping cart.

770-998-0296 | CONTACT US

0item(s)

You have no items in your shopping cart.

Titan Fixed Benzene Detector

Product SKU: TNXSBXX

Quick Overview

The world’s first continuous, benzene-specific monitor!


Set to change the game in refinery applications, Titan is the first truly selective fixed benzene monitor on the market.


Titan is a fixed, continuous, real-time, benzene-specific monitor designed for petrochemical environments, providing the ultimate device for plant and worker safety.


The instrument is wall-mounted with a dynamic detection range or 0 – 20 ppm with 0.1 ppm sensitivity to benzene. Titan samples gas from the environment once per minute and within just 60 seconds an accurate benzene measurement is displayed.


Titan provides an immediate warning alarm system with two operator configurable levels, ensuring workers are kept safe and protected to the standards required on site. The instrument incorporates two relay outputs allowing you to install your own required alarm system.


Titan’s continuous, real-time measurement allows trends to be monitored over time, and communicated via 4-20 mA or RS485. Data is stored internally and can be downloaded remotely for analysis.


Designed to be easily installed and serviced, the modular design allows the Ex d case to be installed well in advance of commissioning. The internal service module can be removed and replaced as a remotely serviceable plug and play cartridge.


Titan incorporates Ion Science patented photoionisation detection (PID) sensor technology with proven resistance to humidity and contamination, ensuring optimal performance, however challenging your environment.

Product Name SKU Price Qty
Titan Benzene Monitor TNXSXBXX-X
$22,500.00
Titan Detector Module TSMXSXXXX-X
$15,000.00
Titan Benzene Monitor and Detector Module Kit TNXSXBXX-X + TSM
$34,000.00

Availability: In stock

Details

Best available benzene detection

  • Fast and accurate detection of benzene down to 0.1 ppm
  • Minute by minute sampling providing continuous real-time data
  • Robust separation method ensures benzene-specific readings
  • Internally regulated heating for stable operation at extreme temperatures

Ultimate safety

  • Clear display & visual alarms for indication of benzene levels
  • Two user-definable independent alarm levels including optional real-time STEL calculation
  • Two relay outputs provide an immediate warning alarm
  • Meets ATEX & IECE, UL and CSA standards

Ease of use & service

  • Modular design for ease of installation and servicing
  • Service-free six months operation
  • Simple 2-button interface for menu navigation
  • 2-year warranty when instrument registered online

Best available PID sensor technology

  • Patented PID sensor technology
  • PID sensor independently verified as best performing on the market
  • In-built humidity resistance with no need to compensate
  • Anti-contamination design for extended field operation

Additional Information

Technical Specifications

Technical Specification

Value/Information

Sensor Type PID, 10.6 eV lamp coupled with selective filtering
Selectivity Benzene specific within typical petrochemical matrix
Range 0 – 20 ppm
Measuring Frequency One minute
Lower Limit of Detection 0.1 ppm
Accuracy
±0.05 ppm or ±10%, whichever is greater
Temperature Stability Internally heated
Sample Flow 200 ml/min
Display
Graphical BW LCD 64 x 128 pixels with back light
Bright LEDs for normal operation, fault and alarm
Two magnetic switches for menu operation
Hazardous Area Safety Approvals
ATEX/IECEx: II 2G Ex d II B+H2 T4 Gb (-20 oC to +55 oC)
Ingress Protection Rating Designed to IP65 (cable gland dependant)
Humidity 0 – 100% RH
Minimum Service Period Selective filter six months
PID lamp one year
Cable Entry Two 3/4 NPT gland threads
Power
Vin (nom) 24 V DC @ 3.2 A (recommended) Vin (max) 32 V DC @ 2.4 A
Vin (min) 19 V DC @ 4.0 A
Communication
Isolated 4-20 mA output
RS 485 Modbus
USB when lid removed with PC software
Data Storage
On board MMC, minimum of six months
Relay
Two isolated outputs, voltage free, 24 V DC @ 1.25 A max
Weight and Dimensions 15 kg (33 lbs)
219 x 219 x 172 mm (8.6 x 8.6 x 6.8” approx.)
 Gas Sample Line 10 m max length, PTFE, 6 mm OD, 4 mm ID
Gas Detector Type PID Gas Detector