Skip to content

Country

RAC 3-Gas Sampler

Original price $7,160.40 - Original price $7,160.40
Original price
$7,160.40
$7,160.40 - $7,160.40
Current price $7,160.40

The RAC 3-Gas Sampler is a wet-chemical system that samples ambient air for up to three different pollutant gases simultaneously and features a thermoelectric system to assure maximum accuracy for SO2 sampling.

The 3-Gas Sampler tests for sulfur dioxide (SO2), nitrogen dioxide (NO2), hydrogen sulfide (H2S), ammonia (NH3), aliphatic aldehydes (R-CHO) and other pollutant gases for which there is a suitable reagent (absorbing solution). This sampler can be used virtually anywhere that line power is available to serve widely diversified gas sampling requirements.

In its basic configuration, the 3-Gas system is designed to collect samples of SO2, NO2 and a third (optional) gas simultaneously. Modular components permit easy changes in sampling train configuration - except for the SO2 arrangement (Station 1) - to meet varying sampling needs.

MAXIMUM SO2 SAMPLING ACCURACY
Tests performed by the U.S. Environmental Protection Agency (EPA) revealed that the accuracy of established wet-chemical SO2 sampling procedures is adversely affected by high ambient temperatures. At 50°C (122°F), for example, about 75% of the SO2 in a collected or stored sample will be lost because of thermal instability within a 24-hour period. Sample degradation begins in the 20°C (68°F) range, with an initial loss factor of approximately 0.9% in 24 hours, and progresses at an increasing rate as the ambient temperature rises. The rate of decay increases five-fold for every 10°C increase in temperature over the range of 20 to 40°C (68 to 104°F).

The RAC 3-Gas Sampler design eliminates this problem in SO2 sampling!

It features a rugged solid-state thermoelectric (Peltier Effect) cooling-heating system that maintains the temperature of the SO2 bubbler and reagent between 5 and 25°C (41 and 77°F) in an ambient temperature range from -25 to 50°C (-13 to 122°F). As a result, all the SO2 collected during a sampling cycle is preserved for optimum accuracy of sample evaluation by standardized wet chemistry and spectrophotometric procedures.

Design

3-GAS SAMPLER COMPONENTS
The RAC 3-Gas sampling system is supplied in a portable all-weather shelter for outdoor use and is furnished complete and ready to operate (reagents not included). This self-contained design includes a heavy-gage steel cabinet with a hinged, lockable top lid, two separate compartments inside and a weather-resistant baked enamel finish. The preassembled complete sampling train, the thermoelectric system and a thermostatically-controlled heater assembly are installed in an insulated compartment; the systems vacuum pump, vacuum gauge and electrical junction box are installed in the second compartment, which has louvers on three sides for heat dissipation. A 3-wire power cord is supplied as standard.

SAMPLING TRAIN:
The RAC gas sampling train assembly includes a polypropylene inlet tube with a conical rain shield and an aluminum rack containing a 3-branch glass inlet manifold, 3 polypropylene 100ml bubblers with interchangeable caps, 3 polypropylene moisture-entrainment traps, 3 critical/limiting orifices, a 3-branch exhaust manifold and all necessary connecting tubing. The sampling rack is positioned on a base module that supports the thermoelectric device for the SO2 bubbler and the non-related compartment heater and blower assembly. The complete sampling module is easily removed for filling, cleaning or changes in configuration (except for the SO2 station). The base module is also easy to remove for periodic inspection or servicing.

The bubblers in Station 1 (SO2 sampling) and Station 3 (third gas sampling) contain orifice-type 0.4±0.1mm glass bubbler tubes. The unit in Station 2 (NO2 sampling) has a fritted glass dispersing element (70 to 100μ).

TEMPERATURE CONTROL:
The SO2 bubbler is encased in an insulating jacket and its temperature is controlled between 5 and 25°C solely by the thermoelectric cooling-heating system. To prevent reagents in the other two bubblers from freezing during cold weather, a constant (variable) temperature above 16°C (60.8°F) is maintained in the insulated compartment by the integral heater, which does not affect the temperature of the specially insulated SO2 bubbler.

The thermoelectric system uses a finned heat sink and blower combination for efficient heat transfer and is protected by a thermal cutout on the heat sink as two fuses in the electrical circuit.

FLOW-REGULATING ORIFICES:
The critical/limiting orifices are precision-bore glass tubing encased in Tygon plastic tubing. The orifices provide a 200 ml/min flow rate (approximate) to all bubblers and are easily cleaned in small ultrasonic baths.

DETACHABLE LEGS:
The all-weather shelter has sturdy angle-iron legs that can be attached flush with the cabinet for carrying/transporting. The legs are securely attached in either the extended or retracted position by rust-resistant bolts threaded into captive nuts.

TIMING MECHANISMS:
To meet a variety of sampling requirements, a 24-hour timer or a 7-day skip timer can be supplied with the RAC 3-Gas Sampler as optional accessories. The 24-hour timer has permanently attached trippers that provide up to 96 on-off cycles in 15-minute increments over a 24-hour period. The 7-day skip timer permits settings one week in advance and has 14 trippers that provide minimum sampling cycles of 3 hours and maximum cycles of 7 days. Both timers are attached to the shelter hinged lid and positioned in the pump compartment.

OPERATION
In operation, the vacuum pump draws ambient air in through the conical rain shield and inlet tube (the rain shield is inverted to prevent precipitation from entering the sampling device). The inlet manifold divides the air stream into equal volumes that flow through PTFE tubing to the bubblers. Each bubbler has a 2-hole cap with a standard glass bubbler tube, either constricted or fritted, on the inlet port. The sample air passes through these tubes into 50ml of reagent contained in each bubbler.

After bubbling through the reagent, the air exhausts through Tygon tubing connected to the outlet port in the cap. Each sample stream then passes through another polypropylene bubbler containing a foam demister followed by a membrane filter. This dual-trap arrangement protects the critical orifices from moisture or other entrainments and helps to maintain continuous full-flow operation for optimum sampling efficiency. The scrubbed air streams then flow through the critical orifices to the exhaust manifold and are discharged through the pump.

In this instrument, contaminate gas samples contact only polypropylene, PTFE or glass before entering the absorbing reagents. This design concept provides for optimum sample collection. All materials in contact with the sample stream are widely recognized for their non-contaminating characteristics when used in a broad range of air pollution instrumentation.

After a sampling cycle is completed, the sampling train assembly is removed from the shelter. The reagent tubes are removed from the rack and the 2-hole caps are replaced with solid, leak-tight, threaded caps. These then are taken to a laboratory for analysis of contents according to appropriate procedures. Tubes containing thermally unstable gas samples, such as SO2, should be transmitted in refrigerated containers.

Features

Meets or exceeds U.S. EPA Reference Method specifications for sampling SO2 in ambient air.


Specifications

Vacuum Pump 1/6 hp, 1.8 cfm free flow, 29" Hg vacuum, continuous duty, overload protection
Electrical 110V/60Hz, 3.7 amp; 220V/50Hz, 1.9 amp
Dimensions, H x W x D 27 x 18 x 14-inches (70 x 46 x 36cm) with legs extended; 15-inches (39cm) H with legs raised
Weight 33 pounds (15kg) without timer
Timer Weights 24-hour: 3 pounds (1.4kg); 7-day: 6 pounds (2.7kg)