Sibata Personal Mini Pump, Model PMP-001

Product SKU: 080870-001

Quick Overview

The personal mini pump PMP-001 is a lightweight, portable air sampling pump equipped with functionality for measuring accumulated flow rates.

Availability: In stock

$934.96

Details

  • A pressure loss correction function is built in, which suppresses intake flow rate fluctuations if  sampling tubes with different pressure loss values are used with the same set flow rate. 
  • A constant flow rate function is built in, which suppresses intake flow rate fluctuations if a sampling material is used with a pressure loss that changes due to sampling. 
  • An organic EL graphics display has been adopted as the indicator, so you can check the flow 
  • rate information even at a dark location. 
  • The product can run for approx. 10 hours on two alkaline batteries (100 mL/min, unloaded conditions). 
  • The USB terminal can be connected to a mobile battery* with an output of at least 5 V DC and 500 mA or to an AC adapter for use as an external power supply. 

 

The personal mini pump PMP-001 is a lightweight, portable air sampling pump equipped with functionality for measuring accumulated flow rates. The flow rate for this pump is 10 mL/min to 300 mL/min, which in the air sampling pump lineup from Sibata is a particularly low flow rate range. It is equipped with a pressure loss correction function and a constant flow rate function. The pump is controlled so as to maintain the set flow rate even if you are using sampling tubes with different pressure loss values, or the pressure loss changes during sampling. As a result, this can be used as an air sampling pump for toxic substances in work environments, indoor environments, and ambient environments.

Additional Information

Technical Specifications

 

Item Code

080870-001
Model PMP-001
Variable Flow Rate Range *1   10 to 300 mL/min
Instantaneous Flow Rate Display  Range  10 to 450 mL/min
Constant Flow Rate Operational Range *1  

10 mL/min: 0 to 10 kPa *2
50 mL/min: 0 to 30 kPa *2
100 mL/min: 0 to 30 kPa
200 mL/min: 0 to 20 kPa
300 mL/min: 0 to 10 kPa

Constant Flow Rate Precision *1   ±5 % or ±5 mL/min of the set flow rate, whichever is larger
Accumulated Flow Rate Setting Range  0.000 to 9999.9 L
Accumulated Flow Rate Display Range  0.000 to 9999.9 L
Time Setting Display Range   000:00:00 to 999:59:59
Internal Flow Meter   Differential pressure type
Pump Type  Diaphragm
Display  Organic EL system
Intake Port Diameter  

External diameter: 6 and 8 mm (The internal diameter of
the tube used is 5 and 7 mm dia.)

Ambient Temperature and Humidity
Range

 0 °C to 40 °C; 10 to 90 % RH (no condensation)
Power Supply  AA batteries, 2 pc., 5 V DC (microB USB)

Continuous Operating Time *3
(When alkaline batteries are used)

 

10 mL/min: Over 10 hours (when unloaded)
100 mL/min: Over 10 hours (when unloaded)

Dimensions  W63 × D29 × H115 mm (not including protruding parts)
Weight  190 g (including batteries)

 

*1 The above-mentioned variable flow rate range, constant flow rate operational range, and constant flow rate precision are specified for use at 1 atmospheric pressure. The abovementioned performance may not be obtained at high altitude locations where the air pressure is lower.
*2 This is the specified range when the low flow rate orifice adapter is used. The flow rate display may vary depending on the operational environment or other conditions.
*3 The operating time is a reference value for a 25 °C environment. It will vary depending on the ambient usage temperature and the usage history.

 

  • If the flow rate is 100 mL/min or less, it may take some time to reach the set value depending on the length of the tube or the attachment position of sampling tubes and other loads, or there may be large fluctuations in the instantaneous flow rate.
  • If the flow rate is 100 mL/min or less, the instantaneous flow rate displayed may momentarily exceed the flow rate precision.
  • The above-mentioned performance may not be obtained immediately after the power is turned ON. Let the pump warm up (with the pump running) for several minutes before use.